RepairXpert Industrial Automation

Safety Circuit Fault — Light Curtain

40003

Safety light curtain beam is interrupted or has alignment fault. Zone motion stopped.

critical general packaging palletizer conveyor
safety light curtain beam guard

Probable Causes (ranked)

Fix Steps

  1. 1 Clear beam path — remove any objects, verify no one is in the zone
  2. 2 Clean light curtain lenses on both emitter and receiver with soft cloth
  3. 3 Check alignment — most light curtains have alignment LEDs, all should be green
  4. 4 If sunlight issue, add shielding or relocate to avoid direct sun exposure
  5. 5 Check light curtain diagnostic display for specific segment fault
  6. 6 Reset safety system and acknowledge at HMI after beam path is confirmed clear

Suggested Replacement Parts

Parts matched to fault category: Light Curtain

Banner EZ-SCREEN LS Light Curtain P/N: LS2TP30-450Q88 Type 4, 30mm resolution, 450mm protective height, PNP OSSD

Prices are estimates. Verify part numbers match your equipment before ordering.