In-line checkweigher or weight scale reading is outside the acceptable tolerance band. Product may be over or under the target weight.

medium general conveyor packaging
weight scale checkweigher tolerance load cell calibration

Probable Causes (ranked)

Fix Steps

  1. 1 Run zero calibration with scale empty — clear any debris from weigh platter or belt
  2. 2 Run span calibration with certified test weight — verify reading matches test weight
  3. 3 Check for vibration sources near the scale — isolate with vibration dampening mounts if needed
  4. 4 Inspect scale conveyor belt — verify it moves freely without dragging on the frame
  5. 5 Verify target weight and tolerance band settings match current product specification
  6. 6 Check load cell cable connections — corrosion or moisture in junction box causes drift
  7. 7 If readings are erratic, swap load cell with known-good unit to confirm failure

Suggested Replacement Parts

Parts matched to fault category: Scale Load Cell

Rice Lake RL75016 S-Beam Load Cell P/N: RL75016-500 500 lb capacity, S-beam, 3mV/V, NTEP certified

Prices are estimates. Verify part numbers match your equipment before ordering.