Palletizer Gripper Release Failure

PAL-006

Palletizer gripper or clamp did not release product at the placement position. Product still held after release command.

medium palletizer
palletizer gripper release vacuum clamp

Probable Causes (ranked)

Fix Steps

  1. 1 Check gripper release mechanism — vacuum blow-off or clamp retract
  2. 2 Verify solenoid valve for release — manual override test
  3. 3 Check blow-off air pressure — should be sufficient to break vacuum seal
  4. 4 Clean gripper contact surfaces — remove product residue
  5. 5 Inspect release position sensors — clean and adjust
  6. 6 If vacuum system, verify blow-off timer is long enough

Field Trick

If vacuum grippers don't release, the blow-off isn't strong enough. Increase blow-off duration by 0.1 second at a time until release is clean.