PKG-002

Case erector reports vacuum loss at suction cups. Cannot pick and open cardboard blanks for case forming.

medium packaging
packaging vacuum case erector suction cup carton

Probable Causes (ranked)

Fix Steps

  1. 1 Check vacuum pump — verify it's running and gauge reads spec (typically -20" Hg)
  2. 2 Inspect suction cups — replace if worn, cracked, or deformed
  3. 3 Check all vacuum hoses for kinks, cuts, and secure connections
  4. 4 Clean suction cups and cardboard blank contact area
  5. 5 Verify vacuum level switch threshold setting — adjust per machine spec
  6. 6 If using venturi generators, check air supply pressure (80-90 PSI typical)

Field Trick

Wet your finger and press it over a suction cup while the pump is running. If you feel strong suction, the cups are fine and the blank surface is the problem. Try a different carton lot.