RepairXpert Industrial Automation

Heat Seal Temperature Out of Range

PKG-007

Heat seal bar temperature is above or below the specified sealing range. Seal quality may be compromised.

medium packaging
packaging heat seal temperature thermocouple ssr

Probable Causes (ranked)

Fix Steps

  1. 1 Check actual temperature with external thermocouple/IR thermometer
  2. 2 Compare reading to controller display — if different, thermocouple is bad
  3. 3 Measure heater element resistance — compare to spec
  4. 4 Check SSR — if failed ON, temperature will overshoot continuously
  5. 5 If failed OFF, heater won't energize — replace SSR
  6. 6 Inspect thermocouple wiring — reseat connections at controller

Field Trick

Touch the SSR heatsink. If it's extremely hot with the heater off, the SSR is shorted ON. Replace it before it damages the seal bar.

Suggested Replacement Parts

Parts matched to fault category: Proximity Sensor

Allen-Bradley 872C Inductive Prox Sensor 18mm P/N: 872C-D5NP18-D4 3-wire DC NPN, 18mm barrel, 5mm sensing range, shielded
IFM Efector IFS204 Inductive Sensor 12mm P/N: IFS204 12mm flush mount, 4mm range, M12 connector, PNP NO
Balluff BES 18mm Inductive Sensor P/N: BES M18MI-PSC80B-S04K 18mm barrel, 8mm range, PNP NO, M12 connector

Prices are estimates. Verify part numbers match your equipment before ordering.

Need a deeper diagnosis with photo analysis and AI-powered troubleshooting?

Run Full Diagnosis
All Fault Codes