Shrink Tunnel Temperature Alarm

PKG-009

Shrink tunnel heating section temperature exceeds setpoint or falls below minimum for proper film shrink.

medium packaging
packaging shrink tunnel temperature heater film

Probable Causes (ranked)

Fix Steps

  1. 1 Check temperature at each zone with external probe
  2. 2 Verify all heater elements — measure resistance on each
  3. 3 Check thermocouple mounting — must be in good thermal contact
  4. 4 Verify blower motors are running — air must circulate for even heating
  5. 5 Clear any product jams inside tunnel
  6. 6 Check SSR operation — use clamp meter on heater circuit

Field Trick

Run your hand along the tunnel exit (carefully). If one side is hot and the other cold, a heater element or blower on the cold side has failed.