Two-Hand Control Timing Violation

SAF-008

Two-hand safety control detected timing violation. Operator did not press both buttons within required time window.

medium general packaging palletizer
safety two-hand control timing operator

Probable Causes (ranked)

Fix Steps

  1. 1 Verify both buttons operate freely — no mechanical binding
  2. 2 Test each button contact block individually with meter
  3. 3 Check timer relay setting — typically 0.5 second window for two-hand activation
  4. 4 Verify wiring — no excessive resistance on either channel
  5. 5 Replace button contact blocks if contacts degraded
  6. 6 Retrain operator on proper two-hand control technique

Field Trick

Two-hand controls must be pressed within 0.5 seconds of each other. If the operator is having trouble, check the buttons — a sticky button adds just enough delay to violate timing.