Fix Steps

  1. 1 Clear any objects from the light curtain detection field — walk the full width of the curtain
  2. 2 Clean emitter and receiver lenses with lint-free cloth — both columns
  3. 3 Check alignment — most light curtains have alignment LEDs on both emitter and receiver, all should be solid green
  4. 4 If one beam is permanently blocked but field is clear, the corresponding LED in the emitter may have failed — check beam-by-beam status
  5. 5 If ambient light interference, install light curtain shrouds or hoods to block direct sunlight
  6. 6 Verify wiring to light curtain controller — check for loose connections on the safety circuit

Field Trick

When a light curtain won't reset but the field looks clear, bend down and look through the curtain at floor level. A small piece of product or a pallet board on the floor can block a bottom beam that you can't see from standing height. The bottom beams are the most commonly blocked because debris collects at floor level.